The approved stand-off installation with thermal separation in external thermal insulation composite systems.

Stand-off installation TherMax 12

The fischer stand-off installation system TherMax 12 is a solution for thermally separated fixation in external thermal insulation composite systems (ETICS) and non-load-bearing layers with a thickness of between 62 mm and 170 mm. In combination with the fischer injection mortars, the system is approved for fixations in concrete and masonry. The approval ensures added safety. The threaded rod has a glass-fibre-reinforced cone and cuts its own way through the plaster and into the insulation material without a setting tool. This saves time and money during the installation process. The fischer TherMax is steplessly adjustable when faced with uneven base materials. It is used to secure heavy loads like awnings, air conditioning units, and satellite antennas in concrete, aerated concrete, and masonry made from perforated and solid brick.
Variantet e produktitDownload of image data

Variantet e produktit

Filtri
Filtri
Miratimet / Raportet e testimit
3 variante produktesh
Contents
Packaging
Amount
GTIN (EAN-Code)
Legjenda = Miratimi ekziston = Miratimi nuk ekziston
Gesehen 3 von 3 Variante(n)

Përparësitë / Përshkrimi

Advantages
  • When combined with the injection mortars FIS EM Plus, FIS V Plus and FIS SB, the stand-off installation is approved for high loads in a range of materials. This allows for a secure fixing.
  • Usage lengths of 62 to 170 mm can be covered with just one TherMax.
  • The plastic cone creates a thermal barrier between the fixture and the inner fixture, and offers an energy-optimised fixing.
  • The glass-fibre-reinforced plastic cone cuts its own way through the ETICS with a positive fit, and allows for a simple, fast and adjustable installation without the need for any special tools.
Youtube VideoYoutube VideoYoutube Video

Aplikimi dhe leja (autorizimi)

Applications
For the thermally separated fixing of:
  • Awnings
  • Canopies
  • French balcony railings
  • Air conditioning units
  • Satellite dishes
Building materials
Approved for:
  • Concrete, cracked and non-cracked
  • Vertically perforated brick
  • Hollow blocks made from lightweight concrete
  • Perforated sand-lime brick
  • Solid sand-lime brick
  • Solid brick
  • Aerated concrete
Detajet (materialet e ndërtimit, ngarkesat, etj.) të çdo miratimi të disponueshëm zbatohen. Dokumentet e mëtejshme mund të gjenden në Qendra e shkarkimit.
Miratimet
  • Z-21.8-1837

Manuali i montimit

Functionality
  • The TherMax 8 is suitable for pre-positioned installation.
  • The self-tapping, glass-fibre-reinforced cone cuts its own way through the plaster into the insulation during installation.
  • The anti-cold cone uses a thermal barrier to minimise heat losses.
  • Installation does not require any special tools.
  • For use in wood without a plug, the wood (see the footnote beneath the load table) and plaster must be pre-drilled: TherMax 8: d02 = 14 mm, h02 = 50 mm.
  • The assortment offers connection possibilities using metric screws M6, self-tapping screws 6.3 mm, chipboard screws 6.0 mm, and 4.5-5.5 mm chipboard screws when using a SX Plus 5 plug.
Mounting Strip 1 Picture
1 / 10

Dokumente për shkarkim

National technical approval - fischer TherMax to be used for anchoring stand-off constructions in concrete and masonry
E vlefshme nga 21.01.2022
deri në 01.12.2026
Stand-off installation TherMax 12 and 16 with load-bearing anchor rod made of zinc-plated steel 8.8 and a displacement of 1 mm
Stand-off installation TherMax 12 and 16 with load-bearing anchor rod made of stainless steel R-70 and a displacement of 3 mm
Installation data TherMax M 12 / M 16
TherMax.
cd-blue-c6785f99-7cp4w